Astm hydrometer 152h pdf file

E1 00 was more effect ive by yielding higher clay contents in the case of the more a ctive soil. Pdf texture determination of soil by hydrometer method. To put it plainly, the numbers obtained from a 151h hydrometer. An api hydrometer can measure the specific gravity of petroleum products, and a sugar or brix hydrometer can. Adjust the range up or down depending on if the hydrometer sinks or is overly buoyant. D422 covered particle size analysis of both the coarse and fine soil fraction using the sieve and hydrometer respectively. Hydrometers shall be of the constantmass, variabledisplacement type. Astm has a work item to come back out with a standard that combines the two. Integrity, honesty, quality and high level of service. Soil analysis hydrometers should be stored in a clean, dry, safe place, and should not be subjected to extreme temperatures. Ktmr32 particle size analysis kansas central lab test. If results from this calculation appear to make no sense, say having 120% of material in suspension, check to make sure the correct formula is being applied to the correct type of hydrometer.

The scale range is 5 to 60 grams with 1 gm divisions astm 152h which meets astm method d422 and aashto method t88. Material used for ballast shall be secured to the lower part of the body, and no loose material of any sort may be inside a hydrometer. Soil analysis astm hydrometers grainger industrial supply. Basic equipment needed for hydrometer analysis in conformance with astm d7928, astm d422 and aashto t 88 standards include stirring. Uniform set of sedimentation cylinders with internal depth of 340 20 mm and capacity of. Hydrometers shall be made of glass, except for the scale, ballasting material, and the thermometric liquid of thermohydrometers. Hb instrument company soil analysis hydrometer 152h 24%. Ele international soil hydrometer type 151h astm d422. Astm d7928 17 standard test method for particlesize. Combining topnotch and uncompromising quality with an affordable price, the hb instrument company soil analysis hydrometer 152h 34792001 can fulfill your laboratory needs while still offering a great value. Grain size distribution documentation of calculations. Hydrometers shall be of the constantmass, variabledisplacement. Dimensions of both hydrometers are the same, the scale being the only item of difference. These data are used to calculate settling velocity v according to the formula.

Astm 151h or 35046306 astm 152h for grainsize analysis of soils. Grain size analysis islamic azad university of isfahan. Includes a circulating pump, which ensures a constant water temperature throughout bath. The s1246 hydrometer type b is similar to the s1245 except that it is graduated 0. Astm method d 422 specifies 35046303 astm 151h or 35046306 astm 152h for grainsize analysis of soils. By clicking submit, you acknowledge that you may be contacted by fisher scientific in regards to the feedback you have provided in this form. A certificate is provided with each hydrometer assuring that the user receives a quality in. Glass sedimentation cylinder 457 mm in height and 63. Laid down by its original founders, the zeal name stands as much for these values now as it did at its inception. Pdf effect of sodium carbonate concentration in calgon. Our astm hydrometers are manufactured in strict accordance to specifications of astm american society for testing and materials for accuracy and design. Density measurement of petroleum products by hydrometer.

Soil analysis astm hydrometers novatech international. V settling velocity cm s l distance cm particles fall in time t. Plain form hydrometer has an approximate length of 280 mm. Particle size distribution and sand equivalent value, soils. Sedimentation by the hydrometer method, particle size distribution.

An api hydrometer can measure the specific gravity of petroleum products, and a sugar or. The devices are floated in a liquid sample, and a graduated scale is read to measure the relative density or specific gravity of the. An astm designation number identifies a unique version of an astm standard. In geotechnical engineering, hydrometer analysis is primarily used to know the grain size distribution of a fine grained soil. Standard test method for particlesize analysis of soils. Specific gravity hydrometers, astm novatech international. Mh the hygroscopic moisture content per astm d 422 8. Dimensional features of astm 152h hydrometer for the purpose of calculating effective depth. Conform to the accuracy requirements of astm hydrometers. Specific gravity is the ratio of the mass of a solid or liquid to be mass of an equal volume of distilled water.

What is the theory behind hydrometer analysis of soil. Click the button below to add the hydrometer, astm hyd 152h to your wish list. Vee gee scientific soil colloid hydrometer, vee gee scientific api, astm hydrometer with safetyblue thermometer, vee gee. Astm d792817, standard test method for particlesize distribution gradation of finegrained soils using the sedimentation hydrometer analysis, astm international, west conshohocken, pa, 2017, back to top. The value of effective depth l for each hydrometer see figure 1 and the sedimentation cylinder in which it is to be used should be calculated as follows. In this post i will share with you the following things. All hydrometers conform to or exceed all specifications set forth in the astm annual book of astm standards, section 14, volume 14. Pdf standard test method for particlesize analysis of soils 1. Sa1 soil hydrometer, astm 151h is graduated to read specific gravity.

Each hydrometer has been calibrated against nist standards and furnished with a nist traceable certificate. Astm hydrometers 126h to 298h icls hydrometers are produced in the united states by outstanding manufacturers known for quality craftsmanship and accuracy of reading. Manufactured strictly in accordance with all applicable astm specifications, these astm hydrometers have become the industry standard for close, accurate readings. If the reading does not fall within the range of the hydrometer you should use a hydrometer that includes the expected reading.

Description hydrometers are manufactured to the exacting specifications provided by nist, astmapi and irs and are calibrated against standards traceable to nist. Hydrometer 151h or 152h conforming to astm e 100 c. We strive to remain as faithful to our roots as possible. Pdf standard test method for particlesize distribution gradation. The hydrometer used is an astm type 152h figure 1, which reads grams of sediment in ml of suspension. Individually serialized hydrometers from grainger help determine standard parameters and a variety of special applications for a wide range of liquids. Standard test method for particlesize analysis of soils1.

This hydrometer comes with a nist traceable certificate of calibration. When measuring with a hydrometer you should have an idea of what reading you are looking for. The density of the soilwater suspension depends upon the concentration and specific gravity of the soil particles and the amount of dispersant added. Active standard astm e100 developed by subcommittee. While the humboldt hydrometer jar water bath can be used for many uses within labs, it was designed specifically for use in providing a consistent temperature bath for storing hydrometer jars in accordance with astm d7928, astm d422, aashto t88 and une 103. Grain size distribution documentation of calculations the calculations used in the program are fairly simple and for the most part follow astm d 422.

B618940100 5 to 60 gramsliter durac soil analysis hydrometer, astm no. D7928 only covered psa of the fine fraction with the hydrometer. Hb instrument durac soil analysis astm hydrometers astm. Hydrometer, soil, astm 152h scale, 5 to 60 gl forney lp. It is my understanding customers wanted an option to specify only the fine psa or. Grain size analysis provides the grain size distribution, and it is required in classifying the soil. Vee gee scientific soil colloid hydrometer, vee gee scientific specific gravity hydrometer for soil analysis, used to. Very gently spin it in control cylinder to remove any particles that may have adhered. Hydrometer analysis of soil is widely used in testing distribution of soil particle sizes. Fisherbrand soil analysis astm hydrometers these hydrometers are used to determine the specific gravity of soil in the range of 0. Balance, set of sieves, cleaning brush, sieve shaker, mixer blender, 152h hydrometer, sedimentation cylinder, control cylinder, thermometer, beaker, timing device. For 152h hydrometers, l, the effective depth, is calculated as follows.

The percent finer is read directly from the hydrometer when the particle density is 2. Astm e100 19 standard specification for astm hydrometers. They are typically calibrated and graduated with one or more scales such as specific gravity a hydrometer usually consists of a sealed hollow glass tube with a wider bottom portion for buoyancy, a ballast such as lead or mercury for stability, and a narrow stem with. We dont know when or if this item will be back in stock. Soil hydrometer type 152h astmaashto graduated 5 to. The determination of the grain size distribution in soils by means of a. If using an astm type 152h hydrometer the calculation for the percentage of soil in suspension is the same for both aashto t 88 and astm d422. Fisherbrand soil analysis astm hydrometers astm 152h. Accommodates eight hydrometer jars which are supported on a stainless steel shelf. Calculation documentation geosystem software home page. Hydrometer analysis of soils test equipment gilson co. Laboratory 2 grain size hydrometer method atterberg limits introduction grain size analysis is widely used for the classification of soils and for specifications of soil for airfields, roads, earth dam s, and other soil embankment cons truction. The hydrometer is removed slowly and placed back into the control cylinder. Dimensions of both hydrometers are the same, the scale being the only item of.

1370 1332 1459 728 505 286 797 202 1000 948 951 1093 422 63 467 773 1182 1299 506 744 636 481 1583 222 1012 1123 337 1362 1258 687 1443 333 1206 651 825 576 722 1060 473